framemountvertical
Frame Mount Vertical

REVERSE OSMOSIS EQUIPMENT

PRODUCTION: 1,800 to 10,800 GPD
OPERATING PRESSURE: 200 PSI

STANDARD FEATURES

  • Powder-coated steel frame
  • Stainless steel multi-stage pump
  • Thin film composite membrane
  • Stainless steel membrane vessel
  • High-pressure nylon tubing
  • Liquid-filled high pressure gauge
  • Liquid-tight wire shrouding
  • Feed water inlet solenoid valve
  • Adjstbl. waste & recycle needle valves
  • Product & waste flow meters
  • 5 micron 10îx4.5î sediment pre-filter
  • Inlet and outlet pre-filter gauges
  • High-pressure brass comp. fittings
  • 110v or 220v-60hz electrical supply
  • Up to 60% feed flow recovery rate

STANDARD ELECTRICAL CONTROLS:

  • NEMA 4 fiberglass enclosure
  • Off/On switch
  • Dual level float switches
  • Low pressure switch
  • Low pressure bypass delay
  • Fused control circuit
  • 24 volt level control circuit

  • Time delay start
  • 30 amp motor contactor
  • Lights: power, running, low pressure, tank full

OPTIONS:

  • High pressure cut-off w/auto restart and manual override
  • 24 volt level control circuit
  • Time delay start
  • 30 amp motor contactor Lights:
  • Automatic hourly flush
  • TDS digital monitor, panel mounted
  • Hour meter
  • Recycle flow meter
  • Tank pressure switch (product)
  • FEED WATER PARAMETERS:

  • Temperature 85° F maximum
  • Pressure 40 – 80 psi maximum
  • TDS 2000 ppm maximum. If higher, consult factory
  • Iron tolerance 0.5 ppm maximum
  • Hydrogen sulfide must be removed
  • Silica tolerance can not be higher than 125 ppm in the concentrate stream. Antiscalant should be considered for any levels over 75 ppm.
  • Turbidity should be removed
  • Hardness must be removed
  • OPERATING PARAMETERS:

    • Operating pressure 200 psi maximum
    • Water recovery up to 60% and is field adjusted by customer. It is not recommended that the recovery be set higher than 50%. Only under certain conditions can the recovery be set higher.
    • pH range 3 – 11
    • Flow rates are determined by the membrane mfgrís. testing criteria of 1500 ppm Nacl solution, 77oF water temperature, 225 psi at 10-15% recovery. Typical membrane salt rejection is 95-95%

    *Actual flow rates may vary depending on the pre-treatment used, water conditions, feed water temperature and applied pressure, etc.

    MODEL *GPD MEMBRANE MOTOR PIPING
    inlet waste prod
    DIMENSIONS
    FMV-1 1,800 ~ 2,000 4″x40″ 1ea. 1.5 HP 1″ 1/2″ 1/2″ 24″ X 29″ 53″H
    FMV-1 1,800 ~ 2,000 4″x40″ 1ea. 1.5 HP 1″ 1/2″ 1/2″ 24″ X 29″ 53″H
    FMV-2 3,600 ~ 4,000 4″x40″ 2ea. 2 HP 1″ 1/2″ 1/2″ 24″ X 29″ 53″H
    FMV-3 4,800 ~ 5,6001,800 ~ 2,000 4″x40″ 31ea. 2 HP 1″ 1/2″ 1/2″ 24″ X 29″ 53″H
    FMV-4 6,300 ~ 7,200 4″x40″ 4ea. 3 HP 1″ 1/2″ 1/2″ 29″ X 29″ 56″H
    FMV-5 8,000 ~ 9,000 4″x40″ 5ea. 3 HP 1″ 1/2″ 1/2″ 29″ X 29″ 56″H
    FMV-6 9,500 ~ 10,800 4″x40″ 6ea. 3 HP 1″ 1/2″ 1/2″ 29″ X 29″ 56″H