Axeon R1-Series

R1-Series Reverse Osmosis Systems are designed for overall superior performance, high recovery rates, minimal energy consumption and offer great savings with low
maintenance and operation costs.

R1-Series Reverse Osmosis Systems feature a new, innovative and expandable design. These systems feature only the highest quality components, including a programmable computer controller with many built-in standard features, a stainless steel booster pump for high performance and corrosion resistance, extra low energy membranes and fiberglass membrane housings for enhanced performance and durability.

R1-Series Reverse Osmosis Systems have been engineered for capacities ranging from 1500 – 9000 gallons per day.

Benefits

  • Fully Equipped and Customizable
  • Expandable and Skid Mounted
  • Decreased Size of Dimensional Footprint
  • Components Easily Accessible
  • Pre-Plumbed, Wired and Assembled
  • Individually Tested and Preserved
  • Low Operation and Maintenance Costs
  • Easy Maintenance and Servicing
  • CE Compliant†
  • 1-Year Limited Warranty
  • Made in the U.S.A.

Standard Features

  • C22 Computer Controller N LED Display
    • Pre-Treatment Lockout
    • Tank Level Input
    • Low Pressure Monitoring and Alarm N TDS Monitoring
    • Feed Flush
  • AXEON Permeate and Concentrate Flow Meters
  • AXEON Concentrate Recycle Flow Meter
  • AXEON Pre-Filter 0 – 100 psi Panel Mounted Glycerin Filled Gauges
  • AXEON Pump Discharge and Concentrate 0 – 300 psi Panel Mounted Glycerin Filled Gauges
  • 5 Micron Sediment Pre-Filter
  • Pentek® Single O-Ring Heavy-Duty Filter Housing
  • AXEON HF4 Extra Low Energy Membrane Elements
  • Fiberglass Membrane Housings – 300 psi
  • Permeate Sample Ports
  • Goulds® Multi-Stage Stainless Steel Booster Pump
  • Feed Solenoid Valve with Manual Bypass
  • Feed Low Pressure Switch
  • John Guest® and Sea-Tech® Push and Pull Fittings with Locking Safety Clips
  • White Powder Coated Aluminum Frame

Options and Upgrades

  • S150 Computer Controller
  • S150 Expander Board
  • S150 Dual TDS Board and Sensor
  • AXEON HF5 Ultra Low Energy Membrane Elements
  • AXEON NF3 Nanofiltration Membrane Elements
  • AXEON NF4 Nanofiltration Membrane Elements
  • Filmtec® LCLE Membrane Elements
  • Filmtec LCHR Membrane Elements
  • Stainless Steel Membrane Housings
  • Hanna® BL 982411 ORP Controller
  • Hanna BL 981411 pH Controller
  • Chemical Pump Outlet
  • Pump Pressure Relief Valve†
  • Blending Valve
  • Permeate Divert Valve
  • High Pressure Tank Switch
  • Caster Wheels
  • Wooden Crate

Array Specifications

Model Vessel Array Vessel Size Vessel Quantity Membrane Size Membrane Quantity
R1-1140 1 4040 1 4040 1
R1-2140 1:1 4040 2 4040 2
R1-3140 1:1:1 4040 3 4040 3
R1-4140 1:1:1:1 4040 4 4040 4
R1-5140 1:1:1:1:1 4040 5 4040 5
R1-6140 1:1:1:1:1:1 4040 6 4040 6

 

 

Models  R1-1140  R1-2140  R1-3140  R1-4140  R1-5140  R1-6140 
Design 
Configuration  Single Pass  Single Pass  Single Pass  Single Pass  Single Pass  Single Pass 
Feed Water Source***  TDS<2,000 ppm  TDS<2,000 ppm  TDS<2,000 ppm  TDS<2,000 ppm  TDS<2,000 ppm  TDS<2,000 ppm 
Standard Recovery Rate  50-75%  50-75%  50-75%  50-75%  50-75%  50-75% 
Rejection and Flow Rates 
Nominal Salt Rejection %  99 99 99 99 99 99
Permeate Flow* gpm (lpm)  1.0 (3.9)  2.1 (7.9)  3.1 (11.8)  4.2 (15.8)  5.2 (19.7)  6.3 (23.7) 
Minimum Feed Flow gpm (lpm)  4.0 (15)  5.1 (19)  6.1 (32)  7.2 (27)  8.2 (31)  9.3 (35) 
Maximum Feed Flow gpm (lpm)  16 (61)  16 (61)  16 (61)  16 (61)  16 (61)  16 (61) 
Minimum Concentrate Flow gpm (lpm) with Recycle Based on 75% Recovery  3 (11)  3 (11)  3 (11)  3 (11)  3 (11)  3 (11) 
Connections 
Feed inch  1 FNPT  1 FNPT  1 FNPT  1 FNPT  1 FNPT  1 FNPT 
Permeate inch  3⁄4 FNPT  3⁄4 FNPT  3⁄4 FNPT  1 FNPT  1 FNPT  1 FNPT 
Concentrate inch  3⁄4 FNPT  3⁄4 FNPT  3⁄4 FNPT  1 FNPT  1 FNPT  1 FNPT 
Membranes 
Membranes Per Vessel  1 1 1 1 1 1
Membrane Quantity  1 2 3 4 5 6
Membrane Size  4040 4040 4040 4040 4040 4040
Vessels 
Vessel Array  1 1:01 1:01:01 1:1:1:1  1:1:1:1:1  1:1:1:1:1:1 
Vessel Quantity  1 2 3 4 5 6
Pumps 
Pump Type  Multi-Stage  Multi-Stage  Multi-Stage  Multi-Stage  Multi-Stage  Multi-Stage 
Motor HP (kw)  1.5 (2)  1.5 (2)  1.5 (2)  1.5 (2)  1.5 (2)  2 (2) 
RPM @ 60 (50 Hz)  3450 (2875)  3450 (2875)  3450 (2875)  3450 (2875)  3450 (2875)  3450 (2875) 
Electrical 
Standard Voltage  220V, 60Hz, 1Ph, 8.7A  220V, 60Hz, 1Ph, 8.7A  220V, 60Hz, 1Ph, 8.7A  220V, 60Hz, 1Ph, 8.7A  220V, 60Hz, 1Ph, 8.7A  220V, 60Hz, 1Ph, 14.1A 
Voltage Options  220V, 50Hz, 1Ph, 14.1A 220V, 50Hz, 3Ph, 7.9A 220V, 60Hz, 3Ph, 6.7A 460V, 60Hz, 3Ph, 3.9A  220V, 50Hz, 1Ph, 14.1A 220V, 50Hz, 3Ph, 7.9A 220V, 60Hz, 3Ph, 6.7A 460V, 60Hz, 3Ph, 3.9A  220V, 50Hz, 1Ph, 14.1A 220V, 50Hz, 3Ph, 7.9A 220V, 60Hz, 3Ph, 6.7A 460V, 60Hz, 3Ph, 3.9A  220V, 50Hz, 1Ph, 14.1A 220V, 50Hz, 3Ph, 7.9A 220V, 60Hz, 3Ph, 6.7A 460V, 60Hz, 3Ph, 3.9A  220V, 50Hz, 1Ph, 14.1A 220V, 50Hz, 3Ph, 7.9A 220V, 60Hz, 3Ph, 6.7A 460V, 60Hz, 3Ph, 3.9A  220V, 50Hz, 1Ph, 14.1A 220V, 50Hz, 3Ph, 7.9A 220V, 60Hz, 3Ph, 7.9A 460V, 60Hz, 3Ph, 4.3A 
Systems Dimensions ** 
L x W x H inch (cm)  29 x 26 x 61 (73 x 66 x 155)  29 x 26 x 61 (73 x 66 x 155)  29 x 26 x 61 (73 x 66 x 155)  33 x 26 x 61 (84 x 66 x 155)  33 x 26 x 61 (84 x 66 x 155)  33 x 26 x 61 (84 x 66 x 155) 
Weight lb. (kg)  250 (110)  290 (130)  360 (160)  460 (210)  590 (270)  750 (340) 

* Product flow and recovery rates are based on equipment test parameters.

** Does not include operating space requirements.
*** Treatment ability of the RO system is dependent on feed water quality. Performance projections must be run for each installation.

Operating Limits

  • Maximum Feed Temperature °F (°C): 85 (29)
  • Maximum Free Chlorine ppm: 0
  • Minimum Feed Temperature °F (°C): 40 (4.4)
  • Maximum TDS ppm: 2,000
  • Maximum Ambient Temperature °F (°C): 120 (48.9)
  • Maximum Hardness gpg: 0
  • Minimum Ambient Temperature °F (°C): 40 (4.4)
  • Maximum pH (Continuous): 11
  • Maximum Feed Pressure psi (bar): 85 (5.9)
  • Minimum pH (Continuous): 5
  • Minimum Feed Pressure psi (bar): 45 (3.1)
  • Maximum pH (Cleaning 30 Min.): 12
  • Maximum Operating Pressure psi (bar): 200 (13.8)
  • Minimum pH (Cleaning 30 Min.): 2
  • Maximum SDI Rating SDI: < 3
  • Maximum Turbidity NTU: 1

Test Parameters: 550 TDS Filtered (5 Micron), De-Chlorinated, Municipal Feed Water, 65 psi (4.5 bar) Feed Pressure, 100 psi (6.89 bar) Operating Pressure, 77 Degrees F (25 Degrees C), Recovery as stated, 7.0 pH. Data taken after 60 minutes of operation.

Low temperatures and high feed water TDS levels will significantly affect the system’s production capabilities. Computer projections should be run for individual applications which do not meet or exceed minimum and maximum operating limits.

Scale prevention measures must be taken to prolong membrane life.